{ "scheme": "CTSpinoPelvic1K v6 (VerSe-native)", "source_of_truth": "scripts/label_scheme.py", "ignore_label": 255, "id_to_name": { "0": "background", "1": "C1", "2": "C2", "3": "C3", "4": "C4", "5": "C5", "6": "C6", "7": "C7", "8": "T1", "9": "T2", "10": "T3", "11": "T4", "12": "T5", "13": "T6", "14": "T7", "15": "T8", "16": "T9", "17": "T10", "18": "T11", "19": "T12", "20": "L1", "21": "L2", "22": "L3", "23": "L4", "24": "L5", "25": "L6", "26": "sacrum", "27": "coccyx", "28": "T13", "29": "S1", "30": "left_hip", "31": "right_hip", "32": "femur_left", "33": "femur_right", "34": "rib_left_1", "35": "rib_left_2", "36": "rib_left_3", "37": "rib_left_4", "38": "rib_left_5", "39": "rib_left_6", "40": "rib_left_7", "41": "rib_left_8", "42": "rib_left_9", "43": "rib_left_10", "44": "rib_left_11", "45": "rib_left_12", "46": "rib_right_1", "47": "rib_right_2", "48": "rib_right_3", "49": "rib_right_4", "50": "rib_right_5", "51": "rib_right_6", "52": "rib_right_7", "53": "rib_right_8", "54": "rib_right_9", "55": "rib_right_10", "56": "rib_right_11", "57": "rib_right_12", "58": "iliolumbar_left", "59": "iliolumbar_right", "60": "nerve_L4_left", "61": "nerve_L4_right", "62": "nerve_L5_left", "63": "nerve_L5_right", "64": "nerve_S1_left", "65": "nerve_S1_right", "66": "psoas_left", "67": "psoas_right", "68": "aorta", "69": "inferior_vena_cava", "70": "iliac_artery_left", "71": "iliac_artery_right", "72": "iliac_vena_left", "73": "iliac_vena_right", "74": "rib_left_lumbar", "75": "rib_right_lumbar", "76": "hardware", "77": "hardware_cage", "78": "hardware_screw_rod", "79": "hardware_plate", "80": "hardware_arthroplasty", "81": "hardware_si_screw", "82": "hardware_osteosynthesis", "255": "ignore" }, "name_to_id": { "background": 0, "C1": 1, "C2": 2, "C3": 3, "C4": 4, "C5": 5, "C6": 6, "C7": 7, "T1": 8, "T2": 9, "T3": 10, "T4": 11, "T5": 12, "T6": 13, "T7": 14, "T8": 15, "T9": 16, "T10": 17, "T11": 18, "T12": 19, "L1": 20, "L2": 21, "L3": 22, "L4": 23, "L5": 24, "L6": 25, "sacrum": 26, "coccyx": 27, "T13": 28, "S1": 29, "left_hip": 30, "right_hip": 31, "femur_left": 32, "femur_right": 33, "rib_left_1": 34, "rib_left_2": 35, "rib_left_3": 36, "rib_left_4": 37, "rib_left_5": 38, "rib_left_6": 39, "rib_left_7": 40, "rib_left_8": 41, "rib_left_9": 42, "rib_left_10": 43, "rib_left_11": 44, "rib_left_12": 45, "rib_right_1": 46, "rib_right_2": 47, "rib_right_3": 48, "rib_right_4": 49, "rib_right_5": 50, "rib_right_6": 51, "rib_right_7": 52, "rib_right_8": 53, "rib_right_9": 54, "rib_right_10": 55, "rib_right_11": 56, "rib_right_12": 57, "iliolumbar_left": 58, "iliolumbar_right": 59, "nerve_L4_left": 60, "nerve_L4_right": 61, "nerve_L5_left": 62, "nerve_L5_right": 63, "nerve_S1_left": 64, "nerve_S1_right": 65, "psoas_left": 66, "psoas_right": 67, "aorta": 68, "inferior_vena_cava": 69, "iliac_artery_left": 70, "iliac_artery_right": 71, "iliac_vena_left": 72, "iliac_vena_right": 73, "rib_left_lumbar": 74, "rib_right_lumbar": 75, "hardware": 76, "hardware_cage": 77, "hardware_screw_rod": 78, "hardware_plate": 79, "ignore": 255 }, "notes": { "74": "A rib articulating with a LUMBAR vertebra. Given its own class rather than being forced to be 'rib 12': a 13th rib is a finding, and numbering it as the twelfth consumed the id the T12 rib needed.", "75": "As 74, right side.", "76": "Surgical instrumentation whose subtype is not distinguished. Neither bone nor any anatomical class; labelled rather than ignored because a cage bridging a disc space makes two vertebrae look fused to any distance measurement, and that must stay separable from congenital fusion.", "77": "Interbody cage or spacer.", "78": "Pedicle screws and rods.", "79": "Plates and other fixation." }, "hardware_note": "Surgical instrumentation, populated from v6 onward (declared but empty in v1-v5). Metal outranks bone: where an implant lay inside a vertebra, hip or femur label, the voxel belongs to the implant. 80 (arthroplasty) REPLACES a joint; 82 (osteosynthesis) holds parts of the SAME bone together -- the distinction matters because pelvic incidence and pelvic tilt are measured from the femoral head, which a prosthesis replaces and fixation does not. Filter on manifest.hardware_labelled before any gap-based analysis: a cage-bridged interspace reads as 'no gap' exactly as a congenitally fused transitional vertebra does." }